In Korea, the seismic design regulations was established since 1988 about regularity scale of structures. However, It was not established about seismic performance and evaluation method as the most existing buildings was constructed before Earthquake-Resistant Design(1988). In this study, It was estimate through internal various existing building examples with Korea Enfrastructure Safety & Technology Corporation(KISTEC)'s seismic performance preliminary evaluation method and using Push Over of Midas-Gen analysis. The purpose of this study provides most conformity seismic performance evaluation process and the appropriate method of calculating the seismic performance index in Korea.