메뉴 건너뛰기
소속 기관 / 학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
(Korea Forest Service) (National Institute of Forest Science) (National Institute of Forest Science) (Chungbuk National University) (Gyeongsang National University) (Woori Tree Hospital) (Chungnam National University)
저널정보
충남대학교 농업과학연구소 Korean Journal of Agricultural Science Korean Journal of Agricultural Science Vol.52 No.2
발행연도
수록면
129 - 140 (12page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
이 논문의 연구방법이 궁금하신가요?
🏆
연구결과
이 논문의 연구결과가 궁금하신가요?
AI에게 요청하기
추천
검색
질문

초록· 키워드

A rise in tree damage caused by internal decay, including breakage and uprooting, especially for trees planted as a street tree in an urban area is of concern specifically for safety issues to human life and property. Although, to predict and proactively respond to such events, structural stability assessment against urban and street trees is being monitored through visual inspection, its difficulty in determining the extent of damage inside trees based solely on such evaluation method requires alternatives that enable to accurately detect and estimate internal structural defects, including cavities and decay. In this regard, non-destructive diagnostic devices, including sonic tomography (SoT) are widely used for estimating internal structural defects of the trees, the accuracy of these techniques varies depending on the tree species, requiring prior reliability analysis of measurement results before field application. Thus, this study aimed to verify whether internal defects in actual wood specimens are accurately reflected by measurements generated by three non-destructive diagnostic devices, including resistance micro-drilling (RESI), SoT and electric resistance tomography (ERT). This was achieved using Prunus × yedoensis that are widely distributed and planted with its popularities in the urban areas of the country. The results showed that the internal structural defects assessed by the wood section inspections were, in general, inappropriately reflected the location and size of the defects with a tendency to under-estimate when compared to those from SoT and ERT, while the RESI was relatively effective for detecting the internal wood decay and cavity the internal structural defects. The findings of this study offer valuable insights as to how measurements obtained from the non-destructive diagnostic techniques should be accurately interpreted for the widespread field application to street trees across the country and further provide a solid foundation for future tree structure evaluations and preventive management practices.
상세정보 수정요청해당 페이지 내 제목·저자·목차·페이지
정보가 잘못된 경우 알려주세요!

목차

  1. Abstract
  2. Introduction
  3. Materials and Methods
  4. Results and Discussion
  5. Conclusion
  6. References

참고문헌

참고문헌 신청

최근 본 자료

전체보기
UCI(KEPA) : I410-151-25-02-093132372