메뉴 건너뛰기

Oscillation of a Magnetic Fluid Plug in a U-Tube ( Effects of Tube Diameter on Oscillating Characteristics )

오류 신고하기

피인용 0

Oscillation of a Magnetic Fluid Plug in a U-Tube ( Effects of Tube Diameter on Oscillating Characteristics )
검색

    초록·키워드

    Effects of tube inner diameter on oscillation of magnetic fluid column, i.e. magnetic fluid plug, in a U-tube are studied for developing a magnetic fluid plug actuator; that is, oscillatory flow of the magnetic fluid is induced by applying the harmonic oscillations of magnetic field, which drives the oscillating flow of distilled water as a working fluid in the U-tube. Experimental work is done using several kinds of U-tubes, whose configurations and radii of curvature are similar each other. However, the dimensions of the diameter are different. The experimental results showed that resonance frequency increases with the inner diameter and that it decreases after it attains the maximum. The maximum amplitude also increases with the diameter in the case that the position of the upper interface of the plug is close to the center of the applied magnetic field. In addition, theoretical consideration, assuming frictional resistance of laminar flow and other flow resistance in the U-tube, is carried out in order to explain the experimental results.

    최근 본 자료 전체보기

      UCI(KEPA) : I410-ECN-0101-2009-550-012582765