    The coal- or biomass-derived syngas contains corrosive gases such as H₂S and HCl. These gases should be removed to avoid corrosion of equipment or to protect catalysts located in the syngas flow. Warm syngas cleanup process purifying contaminant gases at a temperature zone of around 200-500 °C has an advantage of increasing thermal efficiency compared with wet scrubbing method operated at low temperature. HCl can be removed by Na₂CO₃ or K₂CO₃ at warm temperatures. In this study, we investigated the HCl removal performance of spray-dried solid sorbents containing Na₂CO₃ or K₂CO₃. Although these sorbents were originally developed for post-combustion CO₂ capture, active component are basically same as those of the HCl sorbents. Therefore, CO₂ sorbents can be applied as HCl sorbents. The Cl sorption capacity of six sorbents was measured with fixed-bed reactor using simulate ... 전체 초록 보기