3-레벌 GTO 인버터를 위한 새로운 저손실 및 과전압 제한 스너버회로 설계 A New Snubber Circuit for High Efficiency and Overvoltage Limitation in Three-Level GTO Inverters

논문 기본 정보

저자정보
저널정보
대한전기학회 전기학회논문지 電氣學會論文誌 第45卷 第8號
발행연도
수록면
1,132 - 1,145 (14page)
오류 신고하기

피인용 0

3-레벌 GTO 인버터를 위한 새로운 저손실 및 과전압 제한 스너버회로 설계
검색

    초록·키워드

    A new low loss snubber circuit including overvoltage clamping circuit for three-level GTO inverter is presented. The proposed snubber circuit is effective in restriction of the dv/dt and the overvoltage values across each GTO at turn-off and the snubber loss is less than the half that of the conventional RCD snubber circuit. In addition, there is no blocking voltage unbalancing problem between the inner and the outer GTOs that occurs in the case that conventional RCD snubber circuit is used in three-level inverter topology. Experimental results demonstrate that the proposed snubber circuit is very effective for high voltage large capacity three-level GTO inverter systems.