메뉴 건너뛰기
소속 기관 / 학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
고객센터 ENG
주제분류

논문 기본 정보

저자정보
(한전전력연구원) (한전전력연구원) (한전전력연구원)
저널정보
한국연소학회 한국연소학회지 한국연소학회지 제24권 제4호
오류 신고하기

피인용 2

검색

    초록·키워드

    Recently, the abolition policy for coal-fired power plant has been established in KOREA, because they are regarded as the main culprits for the emission of greenhouse gases, fine dusts and nitrogen oxides. But it is expected to cause a huge loss in terms of economical and stable electric energy supply. Therefore the feasibility of the hot wind box repowering method to improve the environmentally friendly as well as high efficiency performance of the aged coal fired power plant was studied in this paper. This method combines the existing boiler with an additional gas turbine in the range of about 30 to 55% of the power output of the existing power plant, and the gas turbine exhaust gas is used as combustion air of existing boiler, and then flue gas of boiler is recovered by heating the feed water. The effect of applying this method is expected to be approximately 7%p increase in electric efficiency, 35% increase in power output, 50% reduction in coal use, 30% reduction in CO₂, and 41% reduction in dust and sulfur dioxide emission.