메뉴 건너뛰기

SOGI를 이용한 단상 계통연계형 인버터의 데드타임 보상 Dead time Compensation of Single-phase Grid-connected Inverter Using SOGI

논문 기본 정보

저자정보
(경남대) (경남대) (경남대) (부산대)
저널정보
전력전자학회 전력전자학회논문지 전력전자학회 논문지 제22권 제2호
발행연도
수록면
166 - 174 (9page)
오류 신고하기

피인용 0

SOGI를 이용한 단상 계통연계형 인버터의 데드타임 보상
검색

    초록·키워드

    This study proposes a compensation method for the dead-time effects on a single-phase grid-connected inverter. Dead time should be considered in the pulse-width modulation gating signals to prevent the simultaneous conduction of switching devices, considering that a switching device has a finite switching time. Consequently, the output current of the grid-connected inverter contains odd-numbered harmonics because of the dead time and the nonlinear characteristics of the switching devices. The effects of dead time on output voltage and current are analyzed in this study. A new compensation algorithm based on second-order generalized integrator is also proposed to reduce the dead-time effect. Simulation and experimental results validate the effectiveness of the proposed compensation algorithm.

    최근 본 자료 전체보기

      UCI(KEPA) : I410-ECN-0101-2017-560-002405658