Optimum Design on Passive Tuned Mass Damper for a Building Subject to Random Base Excitations
검색

    초록·키워드

    A passive Tuned Mass Damper(TMD) has proven simple and effective for reducing severe vibrations of mechanical systems and civil engineering structures with relatively low cost. Most of optimum TMD parameters are determined for a simplified two-degree-of-freedom(two-DOF) system. Therefore, the performance of a TMD in multi-DOF system such as building structures is expected to be different. In this paper, optimal design on passive TMD for a system subject to random base excitations is considered based on relative displacement, relative velocity and absolute acceleration. Optimum TMD parameters are obtained from maximizing the effective damping. Example of a building modeled as single-DOF and eight-DOF systems are studied to illustrate the passive damper design.