    This paper introduces a simple methodology concerning the solar thermal rating (kWh/m²/year) as well as the amount of CO₂ gas emission saved from the installation of a large solar hot water plant. It shows how the measured data of a plant (installation) could be effectively applied to assess its performance ratings. The annual thermal design load (in GJ/year or kWh/year), the collector area and the annual solar fraction of the plant are the major system parameters considered in this regard. Using their experimentally measured data, the authors were able to identify the solar thermal rating of 925 kWh/m²/year and the CO₂ savings of 0.223 ton per m² per year for a solar thermal plant located at the Changi International Airport Services, Singapore.