번역 버튼을 눌러보세요!
A Methodology for Evaluating the Solar Thermal Power Rating and Carbon Dioxide Emission Savings from a Solar Hot Water Plant
A Methodology for Evaluating the Solar Thermal Power Rating and Carbon Dioxide Emission Savings from a Solar Hot Water Plant
초록·키워드
This paper introduces a simple methodology concerning the solar thermal rating (kWh/m²/year) as well as the amount of CO₂ gas emission saved from the installation of a large solar hot water plant. It shows how the measured data of a plant (installation) could be effectively applied to assess its performance ratings. The annual thermal design load (in GJ/year or kWh/year), the collector area and the annual solar fraction of the plant are the major system parameters considered in this regard. Using their experimentally measured data, the authors were able to identify the solar thermal rating of 925 kWh/m²/year and the CO₂ savings of 0.223 ton per m² per year for a solar thermal plant located at the Changi International Airport Services, Singapore.
본문·목차
인공지능 문자 인식 모델을 통해 추출된 텍스트로, 일부 오타나 오류가 포함될 수 있으나 지속적으로 개선 중입니다.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.
최근 본 자료 전체보기
UCI(KEPA) : I410-ECN-0101-2013-563-000889657