음향방출법을 이용한 굽힘피로 손상된 소켓용접배관의 진단 및 감시 Diagnosis and Monitoring of Socket Welded Pipe Damaged by Bending Fatigue Using Acoustic Emission Technique

논문 기본 정보

저자정보
저널정보
한국비파괴검사학회 비파괴검사학회지 비파괴검사학회지 제28권 제4호
발행연도
수록면
323 - 330 (8page)
오류 신고하기

피인용 3

음향방출법을 이용한 굽힘피로 손상된 소켓용접배관의 진단 및 감시
검색

    초록·키워드

    High cycle bending fatigue of socket welded small bore pipe was characterized, and also the fatigue crack initiation of small bore pipe was monitored in situ by the acoustic emission (AE) technique. The STS 316L stainless steel specimens were prepared by gas tungsten arc welding (GTAW) process having the artificial defect (i.e., lack of penetration) and defect free at the root. The fatigue failure was occurred at the toe for high stress and root for relatively low stress. The crack initiation cycles (Ni) was defined to the abrupt increase in AE counts during the fatigue test, and then the cracks were observed by the radiographic test and electron microscope before and after the fatigue crack initiation cycles. The socket welded pipe damaged by bending fatigue was studied regarding the welding defect, failure mode, and crack initiation cycles for the diagnosis and monitoring.