Ventilation of an air cavity in a building envelope by natural force is expected to be an effective measure to release solar radiation. Therefore an experimental model of an air vent wall was constructed to examine the natural ventilation effect. The model of air vent wall has height 2.4m, width 1m and thickness 110㎜. Electric heating panels were burried in the left side of the vent wall. Slit shaped openings at the top and bottom of the air vent wall were set to analyze the thermal characteristics. When heat production on the left side were 80kcal/㎡h and slits were set to 60 ㎜, the average air velocity was 0.30㎧, and removal rate was about 80%. The Effect of the natural ventilation as a heat production was about 85% in spite of increasing heat production.