인문학
사회과학
자연과학
공학
의약학
농수해양학
예술체육학
복합학
개인구독
소속 기관이 없으신 경우, 개인 정기구독을 하시면 저렴하게
논문을 무제한 열람 이용할 수 있어요.
지원사업
학술연구/단체지원/교육 등 연구자 활동을 지속하도록 DBpia가 지원하고 있어요.
커뮤니티
연구자들이 자신의 연구와 전문성을 널리 알리고, 새로운 협력의 기회를 만들 수 있는 네트워킹 공간이에요.
초록·키워드
The purpose of this study was to compare fat oxidation at different exercise modes(treadmill vs cycle ergometer) and different exercise intensities which include maximal fat oxidation exercise intensity(MFOEI), 40%VO₂max and 60%VO₂max for lasting 40min. Ten healthy volunteers of S university(age, 19.7±1.06years; height, 175.2±5.86㎝, weight, 68.7±6.05㎏, body fat, 13.4±2.75%) served as subjects after signing an informed consent form. Following an overnight fast, subjects completed two maximal graded exercise test to determine MFOEI, and submaximal exercise test at different exercise intensities on separate days. To determine MFOEI, it was used Bruce protocol in the treadmill and intial 50W, increment 25W every 2min in the cycle ergometer exercise test. During each test, expired gases were collected and analyzed each 1 min using QMC(USA) metabolic cart. MFOEI was defined as the intensity which resulted in maximal fat kilocarolies per minute(Fkcal) as determined by converting VO₂ to Fkcal at each treadmill and cycle ergometer stage using HER and a Lusk table. MFOEI was analyzed using paired t-test between treadmill and cycle ergometer. And physiological and metabolic variables were analyzed using two way repeated ANOVA at different exercise modes and exercise intensities.
The results were as follows:
1. MFOEI for exercise mode was significantly higher at treadmill(44.2%VO₂max) than at cycle ergometer(37.7%VO₂max)(p<O.05).
2. VO₂ and total kilocarolies per minute(Fkcal) during submaximal exercise were significantly higher with the treadmill than with cycle ergometer at three exercise intensities(p<0.05) and significantly highest at 60%VO₂max for two exercise modes(p<0.05).
3. RER and percent of fat oxidation were not significantly difference between treadmill and cycle ergometer, but there was significantly difference between 40%VO₂max and 60%VO₂max.
4. Fat oxidation was not significantly difference at three exercise modes, but was higher with treadmill than cycle ergometer at 40%VO₂max and MOFOEI.
In conclusion, fat oxidation was not different between MFOEI and 40-60%VO₂max which be recommended for weight control. Therefore, to determine MFOEI which purpose to weight to control, it should be required further study which compare various facotrs such exercise protocol, exercise mode, exercise duration, sex difference, and individual condition.
The results were as follows:
1. MFOEI for exercise mode was significantly higher at treadmill(44.2%VO₂max) than at cycle ergometer(37.7%VO₂max)(p<O.05).
2. VO₂ and total kilocarolies per minute(Fkcal) during submaximal exercise were significantly higher with the treadmill than with cycle ergometer at three exercise intensities(p<0.05) and significantly highest at 60%VO₂max for two exercise modes(p<0.05).
3. RER and percent of fat oxidation were not significantly difference between treadmill and cycle ergometer, but there was significantly difference between 40%VO₂max and 60%VO₂max.
4. Fat oxidation was not significantly difference at three exercise modes, but was higher with treadmill than cycle ergometer at 40%VO₂max and MOFOEI.
In conclusion, fat oxidation was not different between MFOEI and 40-60%VO₂max which be recommended for weight control. Therefore, to determine MFOEI which purpose to weight to control, it should be required further study which compare various facotrs such exercise protocol, exercise mode, exercise duration, sex difference, and individual condition.
본문·목차
인공지능 문자 인식 모델을 통해 추출된 텍스트로, 일부 오타나 오류가 포함될 수 있으나 지속적으로 개선 중입니다.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.
최근 본 자료 전체보기
UCI(KEPA) : I410-ECN-0101-2009-692-016595427