Flat plate slab has been widely used in high rise buildings for its remarkable advantages. However, punching shear failure has become increasingly important issue with the spread of flat plate slab. A flat plate-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In previous, experimental tests were performed to study the capacity of slab-column connections strengthened with various shear reinforcement, and the capacity of the specimens with curve steel reinforcement, experimental studies was performed.
The results of an experiment program on punching shear performance of RC slab-column connection are presented in this paper. Specimens were full-scale representations of a one-story slab in a Korean apartment.
The test results showed that failure mechanism of specimens governed by shear fracture and the strength of specimens were different according to the retrofitting strategies.

목차

Abstract
1. 서론
2. 실험체 계획
3. 실험체 결과 및 분석
4. 결론
참고문헌