Radiant floor heating is the most popular heating system for heating residential houses in Korea. Depending on the heating conditions, on-off valve of each room controls the flow rate of hot water into the room. If some of the rooms are unheated with valve closed, the flow rates to other rooms are increased surpassing design values due to higher pressure difference. The objective of this study is to estimate the energy loss of supply and return pipe lines for two cases. One with design flow rate distribution and the other with excessive flow rates. The radiant floor heating system is modeled and simulated with dynamic simulation software TRNSYS. The results show that the energy loss of a case with excessive flow rate is 1.1% higher than the case with design flow rates.