    Four models are used to estimate the hourly solar radiation on 15 pieces of different tilted photovoltaic (PV) modules in Wuhan, China based on power and solar radiation data during a whole year. The optimum tilt angle (OTA) in Wuhan for yearly and semi-yearly adjustment was determined. Then it was determined that the best mode is the tilt angle of PV module adjusted every half a year. In semi-yearly adjustment, OTA in semi-year of winter and summer is found as 45°, 15°, respectively. Experimental results verify the theoretical calculated values of the OTA with high precision. Energy radio (ER) reveals PV modules with adjustment of tilt angle twice a year has a capability to improve nearly 7% in comparison with fixed type. The best model was chosen based on test results from statistical indicators. The statistical results demonstrate that among the studied models, Liu&Jordan model is the most accurate.