메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Yong-Hyun Kim (Hallym University Sacred Heart Hospital) Yun Kyung Chung (Hallym University Sacred Heart Hospital) Changhwan Kim (Kangdong Sacred Heart Hospital) Eun suk Nam (Kangdong Sacred Heart Hospital) Hyun-Jun Kim (Hallym University Sacred Heart Hospital) Youngsu Joo (Hallym University Sacred Heart Hospital)
저널정보
대한직업환경의학회 대한직업환경의학회지 대한직업환경의학회지 제25권 제5호
발행연도
2013.10
수록면
1 - 7 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Objectives: Dental technicians are exposed to methyl methacrylate(MMA) and hard metal dusts while working, and several cases of hypersensitivity pneumonitis caused by the exposure have been reported. The authors experienced a case of hypersensitivity pneumonitis in a female dental technician who had 10 years’ work experience and report the case with clinical evidence.
Method: The patient’s work, personal, social, and past and present medical histories were investigated based on patient questioning and medical records. Furthermore, the workplace conditions and tools and materials the patient worked with were also evaluated. Next, the pathophysiology and risk factors of pneumonitis were studied, and studies on the relationship between hypersensitivity pneumonitis and a dental technician’s exposure to dust were reviewed. Any changes in the clinical course of her disease were noted for evaluation of the work-relatedness of the disease.
Results: The patient complained of cough and sputum for 1 year. In addition, while walking up the stairs, the patient was not able to ascend without resting due to dyspnea. She visited our emergency department due to epistaxis, and secondary hypertension was incidentally suspected. Laboratory tests including serologic, electrolyte, and endocrinologic tests and a simple chest radiograph showed no specific findings, but chest computed tomography revealed a centrilobular ground-glass pattern in both lung fields. A transbronchial biopsy was performed, and bronchoalveolar washing fluid was obtained. Among the findings of the laboratory tests, microcalcification, noncaseating granuloma containing foreign body-type giant cells, and metal particles within macrophages were identified histologically. Based on these results, hypersensitivity pneumonitis was diagnosed. The patient stopped working due to admission, and she completely quit her job within 2 months of restarting work due to reappearance of the symptoms.
Conclusion: In this study, the patient did not have typical radiologic findings, but pathological evaluation of the lung biopsy from the bronchoscope led to the suspicion of pneumonitis. Under the microscope, the sample contained fibrotic changes in the lung, multinucleated giant cells, and particles in macrophages and was diagnosed as dental technician pneumoconiosis by the pathology. Working as a dental technician had directly exposed her to light metal dust and MMA, and her clinical symptoms and radiologic findings subsided after withdrawal from exposure to the workplace. These outcomes led to the diagnosis of hypersensitity pneumonitis due to MMA exposure and strong work-relatedness.

목차

Abstract
Background
Case presentation
Conclusions
References

참고문헌 (16)

참고문헌 신청

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2016-517-001952864