인문학
사회과학
자연과학
공학
의약학
농수해양학
예술체육학
복합학
지원사업
학술연구/단체지원/교육 등 연구자 활동을 지속하도록 DBpia가 지원하고 있어요.
커뮤니티
연구자들이 자신의 연구와 전문성을 널리 알리고, 새로운 협력의 기회를 만들 수 있는 네트워킹 공간이에요.
논문 기본 정보
- 자료유형
- 학술대회자료
- 저자정보
- 발행연도
- 2015.10
- 수록면
- 93 - 101 (9page)
이용수
초록· 키워드
Monitoring of system cleanliness levels and counting of particulate contaminant are fundamental to achieving hydraulic system reliability as any departure from the specified cleanliness level is often a precursor to future failures. On-line monitoring of cleanliness levels has the advantage of giving data both very quickly and accurately as environmental influences are eliminated. In this way, corrective actions can be promptly implemented. Most on-line instruments are sensitive to system conditions to a greater or lesser extent, but Automatic Particle Counters (APCs) working on light extinction principles are especially sensitive to the presence of optical interfaces caused by such conditions as fluid mixtures, emulsions, free water and air bubbles. These conditions give erroneous data and can result in drawing incorrect conclusions, wasting maintenance time and ultimately, reduced user confidence in cleanliness monitoring. This paper describes such conditions and shows how the correct selection of the analysis technique can result in reliable cleanliness level data.
상세정보 수정요청해당 페이지 내 제목·저자·목차·페이지정보가 잘못된 경우 알려주세요!
목차
- Abstract
- 1. Introduction
- 2 Philosophy of Fluid Cleanliness Monitoring
- 3. Options for Particle Monitoring
- 4. Pit-Falls in Monitoring
- 5. Conclusions
- 6. References
참고문헌
참고문헌 신청최근 본 자료
UCI(KEPA) : I410-ECN-0101-2017-550-000683803