A historically well-known technique for atomizing the liquid water droplets may be electrospray, which is induced by electrostatic charging inside a confined geometry such as needle, nozzle or slit. Based on the Rayleigh’s theory of instability and Taylor’s theory, the electrospray enables to produce fine water droplets as forming a conical shape (Taylor cone) due to the highly concentrated free charge from high intensity of electrical potential between two oppositely charged electrodes. We herein applied this technology to the wet electrostatic precipitator, especially in cyclone structure. The wet electrostatic precipitator has been reported to possess a few flaws such as un-uniform water film formation on the wall, excessive waste water and large energy consumption. Applying the negative potential to the needles and the positive potential to the collector body, we observed sub-100㎛ water droplets are generated by means of an electrospraying process without any pressure. Such highly charged droplets pull the fine particles inside a flue gas, stick to the collector body and then finally free fall down. In this study, we designed and fabricated the electrospray driven wet cyclone electrostatic precipitator, investigating the particle collection performance with the tangential velocity of ~10 m/s at the cyclone inlet, for various voltages and water flowrates. The experimental results show that the effective flowrate through one needle for reaching the PM2.5 collection efficiency of 95% and the power consumption per a needle are measured as 20 ccm and 0.35 W (35 kV and 0.01 mA). Comparing that the the ratio of water to flue gas and power consumptions of the previously commercialized wet electrostatic precipitators for the treatment capacity of 50 CMM have been reported as 1.0 L/m<SUP>3</SUP> and 840 kW, our measurement gave us 0.2 L/m<SUP>3</SUP> and 175 W, which are merely 20% and 20.8% over those of the commercialized one, respectively

목차

Abstract
1. 서론
2. 연구 방법
3. 실험 결과
4. 결론
References

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0