메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
장희라 (원광대학교) 송현옥 (익산병원) 김재수 (원광대학교)
저널정보
한국생활환경학회 한국생활환경학회지 한국생활환경학회지 제25권 제2호
발행연도
2018.4
수록면
183 - 193 (11page)
DOI
10.21086/ksles.2018.04.25.2.183

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

이 논문의 연구 히스토리 (2)

초록· 키워드

오류제보하기
Magnetic resonance imaging (MRI) in modern medical science is a method of imaging by putting a person into a device generating a magnetic field to generate high frequency and analyze the signals generated from inside the body. However, MRI causes serious noises while coils move within the device to generate a strong magnetic field. These noises can give serious physical and psychological distress to patients. For this reason, various data are needed to reduce the noises generated from MRI operation; however, South Korea has had almost no relevant research. From this perspective, this study selected four MRI devices with different degrees of a magnetic field, measured noises for each source of MRI operation, and analyzed the waveform, the sound pressure level based on frequency, and the weighted sound level or dB(A). On the basis of these data, MRI operation noises were evaluated with dB(A) and NR to determine how much they affected patients. The MRI operation noises could be divided into four waveforms and most of them were extremely high in the medium-to-high frequency bands, with the exception of the WN noises. When the MRI operation noises were evaluated with dB(A), the NR curve, and PSIL, 0.3T of the magnetic field led to 57.1-64 dB(A), NR 53-62, and 1.98-3.96 m for medium sound, and 4.26-8.31 m for loud sound, with no significant effect on patients. In contrast, 1-3T of the magnetic field led to 74.4-90.9 dB(A) and NR 72-89 for Noise T1, 85.9- 91.7 dB(A) and NR 83-90 for Noise T2, 90.5-28.1 dB(A) and NR 87-98 for Noise D, 79.4-89.8 dB(A) and NR 77- 89 for Noise G, 0.06-0.65 m for medium sound, and 0.12-1.29 m for loud sound in terms of PSIL. Because of patients’ exposure to very serious noises, it is urgent to take measurements then. In particular, 1-3T of the magnetic field, which can affect patients, led to 100-1,000 Hz of grading frequency for the NR curve; therefore, it is essential to lower the noise level of this band with the objective of reducing damages from the exposure to serious noises during an MRI scan.

목차

Abstract
1. 서론
2. MRI실의 제원 및 측정방법
3. MRI 작동소음의 특성
4. MRI작동소음의 영향평가
5. 결론
REFERENCES

참고문헌 (13)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2018-590-002074635