메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Eun-Jong Oh (Doosan Heavy Industries & Construction) Dong-Hwa Lee (Doosan Heavy Industries & Construction) Sung-Woo Cho (Doosan Heavy Industries & Construction) Yun-Il Choi (Doosan Heavy Industries & Construction) Ki-Woo Nam (Pukyong National University)
저널정보
대한용접·접합학회 대한용접·접합학회지 大韓熔接·接合學會誌 第38卷 第3號
발행연도
2020.6
수록면
278 - 288 (11page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
The holding time during solution heat treatment of unstabilized austenitic stainless steels as specified in the nuclear regulatory requirements was investigated. The sensitized 2.54㎝ thick specimens held at 675℃ for 1 h were rejected by ASTM A262 test, due to the large amount of chromium carbide precipitated in the form of 50~300㎚ particles at the grain boundaries. They also showed about 10.8% of DOS in the DL-EPR test. However, solution heat treatment of the sensitized specimens at 1,038℃ and 1,121℃ for at least 1 min resulted in the complete dissolution of chromium carbide into the grains, and they passed ASTM A262 test and showed less than 0.01% of DOS in the DL-EPR test. As a result of solution heat treatment at 1,038℃ for 5 h of the 25.4㎝ thick specimen sensitized at 675℃ for 10 h, it passed ASTM A262 and DL-EPR test at any position in the specimen thickness. While the specimen surface showed a step structure without the precipitation of chromium carbide and a DOS less than 0.01%, towards the center, a dual structure was observed. It exhibited about 0.6% of DOS due to the longer exposure time to the sensitization range of 427~816℃. Considering the minimum time in which the chromium carbide precipitated at the grain boundary at 1,038℃ was completely dissolved into the grain, and the maximum delay time for the center of the specimen to reach 1,038℃ rather than the surface, the holding time for complete solution heat treatment to the center was found to be up to 2 min per 2.54㎝ of material thickness. The solution heat treatment for 0.5~1.0 h per 2.54㎝ of material thickness at 1,038~1,121℃, which is employed in the nuclear power industry, was proven to prevent grain boundary corrosion by inhibiting the sensitization of unstabilized austenitic stainless steels.

목차

Abstract
1. Introduction
2. Experimental Method
3. Test Results and Discussion
4. Conclusion
References

참고문헌 (12)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-ECN-0101-2020-581-000842277