메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
저널정보
한국생체재료학회 생체재료학회지 생체재료학회지 제23권 제4호
발행연도
2019.1
수록면
228 - 235 (8page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Inadequate retention and gradual debonding of intracanal post from root dentin is a major cause of failure of endodontically treated teeth restored with fiber post. Main body: This study aimed to assess the effect of surface treatment of quartz fiber posts with different powers and motion directions of Er,Cr:YSGG laser on their pull-out bond strength to root dentin in endodontically treated premolar teeth. In this study, 105 fiber posts were divided into 7 groups according to their surface treatment with different powers of Er,Cr:YSGG laser at 2780 nm wavelength, 20 Hz frequency and 150 μs pulse duration in circumferential (C) or longitudinal (L) motion directions: Control group (no treatment), 0.5W laser in longitudinally (L0.5), 1.0W laser in longitudinally (L1), 1.5W laser in longitudinally (L1.5), 0.5W laser in circumferentially (C0.5), 1.0 W laser in circumferentially (C1) and 1.5W laser in circumferentially (C1.5). After cementation, pull-out bond strength was measured in Newton (N). Each sample was inspected under a stereomicroscope at × 25 magnification to determine the mode of failure. Two samples of each group were inspected under a scanning electron microscope (SEM). Data were analyzed using two-way ANOVA and Tukey’s test with significant level of 0.05. The pull-out bond strength of 0.5W groups had significant differences with the control group (P = 0.009). The bond strength of 1.0W and 1.5W groups were not significantly different (P = 0.630) but were higher than the control and 0.5W groups (P < 0.001). Motion direction of laser irradiation had no significant effect on the bond strength (P = 0.384). The interaction effect of power and motion direction of laser irradiation had no significant effect on the bond strength (P = 0.092). Conclusion: Fiber posts treated with 0.5, 1.0 and 1.5W Er,Cr:YSGG laser showed higher bond strength to dentin compared to posts with no surface treatment. However, the motion directions of laser irradiation had no significant effect on the bond strength. In order to minimize damage to post surface and achieving maximum bond strength, longitudinal surface treatment of posts with 1.0W power of Er,Cr:YSGG laser is recommended.

목차

등록된 정보가 없습니다.

참고문헌 (34)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0