This study was performed to obtain the basic data which could be used for the modification of the manual center-burner-type rice-husk furnace into a small scale automatic type for the multi-purpose use in the farm. For this purpose, first, the utilization feasibility of the rice-husk furnace in the farm was analyzed briefly in aspects of available amount of rice-husk for the fuel, annual operation time and replaceble amount of residential heating energy with rice-husk in the farm. For the experiment a prototype furnace geared with an automatic feeding device was fabricated, and feed rate, mold size and chimney height were changed to investigate the combustion efficiency of rice-husk and thermal efficiency of the furnace. Also, optimum and limiting operational factors were observed in each treatments. The results obtained are summarized as follows. 1. If the rice-husk is intensively used for residential heating in the farm for winter season, on an average 51 percent of the total heating energy can be replaced with the rice-husk. Therefore, development of a small scale automatic rice-husk furnace was recognized to be feasible. 2. The operational condition depending on husk-feed rates was very important factor for successive steady burning operation of the given furnace. When the feed-rate was 1.5 kg/hr, the top of the burning zone should be kept at the position about 55 cm from the bottom of the combustion chamber with the periodic removal of ash (termed as steady state position), which was 18 cm above the mold waist. When the feed rates were 2.4 kg/hr and 3.0 kg/hr, the steady state position was at about 4 cm above the mold waist. 3. The mold size affected inflow rate of air into the furnace and consequently CO content in the exhaust gas. The relatively bigger mold gave positive effect on the air-inflow rate. 4. When the husk-feed rates were 1.5 kg/hr, 2.4 kg/hr, 3.0 kg/hr, the combustion efficiencies of the rice-husk were 98.5%, 97.4% and 95.0%, the thermal efficiencies of the furnace were 93.4%, 93.2% and 87.6%, and CO content in the exhaust gas were 1.21%, 1.03%, and 2.43%, respectively. The air-inflow rates were decreased with the increase of feed rates. When the amount of excess air was 30-40%, the CO content in the exhaust gas was at the minimum level. 5. When the chimney height was lowered from 260 cm to 96 cm, the air-inflow rate was slightly decreased, but the average temperature in the combustion chamber, CO content in the exhaust gas and combustion and thermal efficiencies were not changed significantly. 6. The incidental problems associated with the protytype furnace were accumulation of the ash inside the mold, accumulation of the cinder between the outer-drum of the furnace and the combustion chamber wall, and accumulation of the cinder in the chimney.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0