메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
김종국 (서울대학교 약학대학) 최한곤 (서울대학교 약학대학) 이사원 (서울대학교 약학대학) 고종호 (서울대학교 약학대학) 이미경 (서울대학교 약학대학)
저널정보
한국응용약물학회 The journal of applied pharmacology : the official journal of the Korean Society of Applied Pharmacology The journal of applied pharmacology : the official journal of the Korean Society of Applied Pharmacology 제6권 제2호
발행연도
1998.1
수록면
213 - 218 (6page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
A novel in situ-gelling and mucoadhesive acetaminophen liquid suppository was developed to improve the patient compliance of conventional solid suppository. In this study, acetaminophen liquid suppository, Likipe $n_{R}$, [aminophen/Poloxamer 407/Poloxamer 188/so4ium alginate (5/15/19/0.6%)] with relation temperature at 30-36 "C and suitable gel strength and bioadhesive force, dissolution pattern similar to conventional solid type suppository, Suspe $n_{R}$, was developed. Furthermore, the bioequivalence of two acetaminophen products was evaluated in 16 normal male volunteers (age 22-27 yr, body weight 56-72 kg) following sidle rectal administration. Test product was Likipe $n_{R}$ suppository (Dong-Wha Pharm. Corp., Korea)and reference product was Suspe $n_{R}$204-212 suppository (Hanmi Pharm. Corp., Korea). Both products contain 125 mg of acetaminophen. Four Suppositories of the test and the reference product were administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of acetaminophen was accomplished using HPLC. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{-2}$4h/) (30.14$\pm$8.64 vs 27.98$\pm$ 6.53 $\mu$g .h/ml), maximum plasma concentration ( $C_{max}$) (3.29$\pm$0.87 vs 3.60$\pm$0.66 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.91 $\pm$0.55 vs 2.69$\pm$0.60 h). The differences of mean AUCo $_{24h}$, C-a. and T-between the two products (7.18%, 9.58% and 7.53%, respectively) were less than 20%. The power (1-7) and treatment difference ($\Delta$) for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ were more than 0.8 and less than 0.2, respectively at $\alpha$=0.1. The confidence limits for AU $Co_{24h}$, $C_{max}$ and $T_{max}$ (-0.81 ~13.55%, -1.56~ 17.60 and -3.81 ~18.87%, respectively) were less than $\pm$ 20% at $\alpha$=0.1. These results suggest that the bioavailability of Likipe $n_{R}$ suppository is not significantly different from that of Suspe $n_{R}$ suppsitory. Therefore, two products are bio-equivalent based on the current results.results.lts.sults.results.lts.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0