Jung, Bongsu (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) Seo, Kwang-Suk (Department of Dental Anesthesiology, School of Dentistry, Seoul National University) Kwon, Suk Jin (Department of Dental Anesthesiology, School of Dentistry, Seoul National University) Lee, Kiyoung (R&D Center, Bionet Co., Ltd.) Hong, Suyong (R&D Center, Bionet Co., Ltd.) Seo, Hyounsoon (R&D Center, Bionet Co., Ltd.) Kim, Gi-Young (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) Park, Geun-Mook (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) Jeong, Juhee (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation) Seo, Soowon (Medical Device Development Center, Daegu-Gyeongbuk Medical Innovation Foundation)
저널정보
대한치과마취과학회 Journal of dental anesthesia and pain medicine Journal of dental anesthesia and pain medicine 제16권 제4호
발행연도
2016.1
수록면
303 - 307 (5page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: In dental intravenous sedation, continuous intravenous infusion of a low-dose drug requires an infusion pump such as a syringe pump. To develop a new syringe pump for clinical use, the functions of the pump must meet certain international standards. Various safety and efficacy tests must be performed on the syringe pump, as stipulated by these standards, and an approval must be received from the approving agency based on such test results. Methods: The authors of the present study developed a novel syringe pump and performed efficacy evaluation by testing its infusion speed at 1 and 25 ml/h, and infusion performance testing at 2 and 24 h. Moreover, performance evaluation was conducted by comparing the novel pump to an existing pump with the infusion speed varied from 1 to 5 ml/h. Results: In the efficacy testing on the newly developed syringe pump, infusion with the infusion speed initially set to 1 ml/h resulted in infusion speeds of 1.00 and 0.99 ml/h in the 2- and 24-h assessment, respectively. Changing the infusion speed setting to 25 ml/h resulted in an infusion speed of 25.09 and 23.92 ml/h in the 2- and 24-h assessment, respectively. These results show no significant differences when compared with other commercially available pumps. Conclusions: The efficacy testing of the newly developed syringe pump showed the accuracy to be within tolerance. Based on these findings, we believe that the newly developed syringe pump is suitable for clinical use.

목차

등록된 정보가 없습니다.

참고문헌 (11)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0