메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Osipov, M.A. (National Research Nuclear University MEPhI [Moscow Engineering Physics Institute], International Laboratory of High Magnetic Fields and Low Temperatures) Abin, D.A. (National Research Nuclear University MEPhI [Moscow Engineering Physics Institute], International Laboratory of High Magnetic Fields and Low Temperatures) Pokrovskiy, S.V. (National Research Nuclear University MEPhI [Moscow Engineering Physics Institute], International Laboratory of High Magnetic Fields and Low Temperatures) Mineev, N.A. (National Research Nuclear University MEPhI [Moscow Engineering Physics Institute], International Laboratory of High Magnetic Fields and Low Temperatures) Rudnev, I.A. (National Research Nuclear University MEPhI [Moscow Engineering Physics Institute], International Laboratory of High Magnetic Fields and Low Temperatures)
저널정보
한국초전도저온학회 한국초전도·저온공학회논문지 한국초전도·저온공학회논문지 제17권 제1호
발행연도
2015.1
수록면
21 - 24 (4page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
New results of dependence of magnetic field, trapped by a stack of HTS tapes, on amount of tapes in a stack are reported. Commercial GdBCO tape 12 mm width and without Cu layer was used for the research. Tape was divided in square pieces $12{\times}12mm^2$ from which stacks were formed. Filling factor of the tape was about 1.4%. Measurements were carried out for stacks with height from 5 to 250 pieces and at wide temperature range from liquid helium to liquid nitrogen. Both FC (field cooling) and ZFC (zero field cooling) cooling methods were used in the research. These two methods show matching results with good accuracy. As a result dependences of trapped magnetic flux on amount of tapes for different temperatures were received. Research shows, that with increasing height of the stack trapped magnetic field value reach saturation at about 60 tapes in a stack for low temperatures. From 60 to 100 tapes increase of magnet flux is only 5%. Thus increase amount of tapes in a stack is not profitable. Also investigation of trapped magnet field relaxation was carried out. Relaxation speed decreases with increasing amount of elements. It means that the higher the stack is, the longer trapped flux will be held in cause of the same temperature.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0