This Study conducted the field performance evaluation through building the test houses in order to evaluate on the consumption characteristics of cooling energy in the blind-integrated window system developed for reducing the cooling load originated from incoming solar radiation through window on summer. According to the comparison and analysis against the general double-layer window, there was the difference of about $6^{\circ}C$ between indoor and outdoor surface temperature and the electricity consumption of blind-integrated window was reduced up to about 26% and by 11% in daily average: the heat loss and heat gain through window was drastically reduced compared to the general double-layer window, so the blind-integrated window was found to be effective to the reduction of solar radiation load of cooler through window.