메뉴 건너뛰기
소속 기관 / 학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
고객센터 ENG
주제분류

논문 기본 정보

저자정보
(한국건설기술연구원) (서울시립대학교) (한국건설기술연구원) (한국건설기술연구원) (한국건설기술연구원)
저널정보
한국생활환경학회 한국생활환경학회지 한국생활환경학회지 제28권 제2호
오류 신고하기

피인용 0

검색

    초록·키워드

    Thermal property degradation of building insulation materials were analyzed by accelerated laboratory methods defined in ISO 11561 to verify thermal resistance change experimentally. Selected samples varied within one to three days from production date. Primary tests were executed for more than 3,000 hrs for XPS (Extruded PolyStyrene) and Rigid poly urethane, respectively. Secondary tests were carried out for approximately 1,500 hrs for special and first grade of XPS. Measured values of thermal resistance were analyzed to estimate the thermal resistance values of 25 year-time-lapse and to compare with 25 year-average value. It was observed that thermal property of special grade XPS was estimated to decrease after 25 years by 37 to 41% from the initial value. Grade 1 XPS showed relatively better results as of 21 to 27%. In addition, Rigid poly urethane 40K revealed property degradation pattern of 21 to 27% from the production stage.

    최근 본 자료 전체보기

      UCI(KEPA) : I410-ECN-0101-2021-590-001685993