메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Abhishek Srivastava (Primus Hospital) Geetanjali Nanda (Mahajan Imaging Center) Rajat Mahajan (Indian Spinal Injuries Center) Ankur Nanda (Indian Spinal Injuries Center) Nirajana Mishra (Economist and Data Analyst) Srinivasa Karmaran (Tejaswani Hospital) Sahil Batra (Caremax Superspeciality Hospital) Harvinder Singh Chhabra (Indian Spinal Injuries Center)
저널정보
대한척추외과학회 Asian Spine Journal Asian Spine Journal Vol.11 No.6
발행연도
2017.1
수록면
847 - 853 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Study Design: A retrospective computed tomography (CT)-based morphometric study of 82 occipital condyles in the Indian population, focusing on critical morphometric dimensions with relation to placing condylar screws Purpose: This study focused on determining the feasibility of placing occipital condylar screws in an Indian population using CT anatomical morphometric data. Overview of Literature: The occipital condylar screw is a novel technique being explored as one of the options in occipitocervical stabilization. Sex and ethnic variations in anatomical structures may restrict the feasibility of this technique in some populations. To the best of our knowledge, there are no CT-based data on an Indian population that assess the feasibility of occipital condylar screws. Methods: We measured the dimensions of 82 occipital condyles in 41 adults on coronal, sagittal, and axial reconstructed CT images. The differences were noted between the right and left sides and also between males and females. Statistical analysis was performed using the t -test, with a p- value of <0.05 considered significant. Results: Mean sagittal length and height were 17.2±1.7 mm and 9.1±1.5 mm, respectively. Mean condylar angle/screw angle was 38.0°±5.5° from midline, with mean condylar length and width of 19.6±2.6 mm and 9.5±1.0 mm, respectively. Average coronal height on the anterior and posterior hypoglossal canal was 10.8±1.4 mm and 9.0±1.4 mm, respectively. The values in females were significantly lower than those in males, except for screw angle and condylar width. Based on Lin et al.’s proposed criteria, eight of 82 condyles were not suitable for condylar screws. Conclusions: Preliminary CT morphometry data of the occipital condyle shows that condylar screws are anatomically feasible in a large portion of the Indian population. However, because a small number of population may not be suitable for this technique, meticulous study of preoperative anatomy using detailed CT data is advised.

목차

등록된 정보가 없습니다.

참고문헌 (2)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0