메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Kim Yeun-Yoon (Department of Radiology and Center for Imaging Science Samsung Medical Center Sungkyunkwan Universi) Min Ji Hye (Department of Radiology and Center for Imaging Science Samsung Medical Center Sungkyunkwan Universi) 황정아 (삼성서울병원) 정우경 (삼성서울병원) Sinn Dong Hyun (Department of Medicine Samsung Medical Center Sungkyunkwan University School of Medicine Seoul Kore) 임효근 (성균관대학교)
저널정보
대한초음파의학회 ULTRASONOGRAPHY ULTRASONOGRAPHY Vol.41 No.3
발행연도
2022.7
수록면
519 - 529 (11page)
DOI
10.14366/usg.21198

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Purpose: This study investigated the utility of second-line contrast-enhanced ultrasonography (CEUS) using Sonazoid in Liver Imaging Reporting and Data System category 3 (LR-3) and 4 (LR-4) observations on gadoxetate-enhanced magnetic resonance imaging (MRI).Methods: This retrospective study included LR-3 or LR-4 observations on gadoxetate-enhanced MRI subsequently evaluated with CEUS from 2013 to 2017. The presence of MRI features, CEUSarterial phase hyperenhancement (CEUS-APHE), and Kupffer phase defect (KPD) was evaluated. Multivariable logistic regression analysis was performed to identify significant imaging features associated with the diagnosis of hepatocellular carcinoma (HCC). The optimal diagnostic criteria were investigated using the McNemar test.Results: In total, 104 patients with 104 observations (63 HCCs) were included. The presence of both CEUS-APHE and KPD on CEUS enabled the additional detection of 42.3% (11/26) of LR-3 HCCs and 78.4% (29/37) of LR-4 HCCs. Transitional phase (TP) hypointensity (adjusted odds ratio [OR], 10.59; P<0.001), restricted diffusion (adjusted OR, 7.55; P=0.004), and KPD (adjusted OR, 7.16; P=0.003) were significant imaging features for HCC diagnosis. The presence of at least two significant imaging features was optimal for HCC diagnosis (sensitivity, specificity, and accuracy: 88.9%, 78.1%, and 84.6%, respectively), with significantly higher sensitivity than the presence of both CEUS-APHE and KPD (sensitivity, specificity, and accuracy: 63.5% [P=0.001], 92.7% [P=0.077], and 75.0% [P=0.089], respectively).Conclusion: The combined interpretation of gadoxetate-enhanced MRI and second-line CEUS using Sonazoid, focusing on TP hypointensity, restricted diffusion, and KPD, may be optimal for further characterizing LR-3 and LR-4 observations.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0