Simone Marconcini (Fundationf for Research Istituto Stomatologico Toscano Camaiore 55041 Italy) Enrica Giammarinaro (Fundationf for Research Istituto Stomatologico Toscano Camaiore 55041 Italy) Giacomo Oldoini (Fundationf for Research Istituto Stomatologico Toscano Camaiore 55041 Italy) Annamaria Genovesi (Fundationf for Research Istituto Stomatologico Toscano Camaiore 55041 Italy)
저널정보
한국치위생과학회 치위생과학회지 치위생과학회지 제23권 제1호
발행연도
2023.3
수록면
13 - 19 (7page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Background: Periodontitis is a chronic inflammatory condition associated with dysbiosis of the oral microbiota. The aim of the present clinical study was to explore the adjunctive effect of ozonized water irrigation in the circuits of ultrasonic scalers for the full-mouth decontamination of patients with periodontitis Stage I or II.Methods: The study was a randomized, single-blinded, parallel-group clinical trial. The test group (n=25) was treated with ultrasonic scalers irrigated with ozonized water, whereas the control group (n=25) received normal tap water irrigation within the ultrasonic scalers used during the professional mechanical debridement. Full mouth plaque score, bleeding score, probing pocket depth, and the gingival index were evaluated at baseline, two, and 4 weeks after treatment. The pain perceived and dental anxiety were also assessed after treatment by means of the visual analog scale (VAS). Results: All periodontal parameters resulted in significant improvement for both study groups. The effect of the treatment group on the gingival index was significant, in particular, patients in the test group experienced a greater reduction in this score. No significant differences could be observed with regards to the average probing depth, full mouth plaque index and bleeding score. Patients treated with ozonized water running in the circuits of ultrasonic scalers displayed also lower scores for pain and dental anxiety. Conclusion: The present study showed a significant clinical effect on gingival inflammation attributable to adjunctive ozone irrigation during nonsurgical periodontal therapy. Further studies, including patients with severe periodontitis and greater sample sizes, are recommended to test the clinical effect of ozonized water in the circuits of ultrasonic scalers.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0