메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Zhang Shuaijun (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University) Hou Gangling (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University) Yang Chengyu (State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University) Yue Zhihua (College of Aerospace and Civil Engineering, Harbin Engineering University) Wang Yuzhu (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University) He Min (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University) Sun Lele (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University) Cai Xuesong (Yantai Research Institute of Harbin Engineering University, Harbin Engineering University)
저널정보
한국원자력학회 Nuclear Engineering and Technology Nuclear Engineering and Technology Vol.56 No.7
발행연도
2024.7
수록면
2,595 - 2,609 (15page)
DOI
10.1016/j.net.2024.02.019

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
This paper introduces a base isolation system-tuned mass damper inerter (BIS-TMDI) hybrid system to the AP1000 nuclear power plant (NPP), which reduces seismic damage potential of the NPP structure. The effects of fluid-structure interaction (FSI) caused by the passive containment cooling system water storage tank (PCCWST) on NPP’s seismic performance are investigated. The FSI of water tank theoretical model is considered based on the Housner’s model, and a series of time history analyses are performed to prove the rationality of the proposed model. Three single-objective optimization strategies are employed to minimize the relative displacement variance and absolute acceleration variance of the upper structure, as well as the filtered energy index (FEI). Furthermore, a multi-objective optimization strategy considering all these three indexes is proposed to obtain optimal parameters of vibration control. The influence of vibration control strategies on the relative deformation and acceleration of the upper structure is explored with various water level ratios. The analytical results indicate that the proposed BIS-TMDI strategy has significantly reduced the NPP structure’s seismic response. The effectiveness of the vibration control strategy is influenced by the water level ratio, emphasizing the significance of designing an appropriate water level ratio to reduce NPP structure’s seismic response.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0