인문학
사회과학
자연과학
공학
의약학
농수해양학
예술체육학
복합학
지원사업
학술연구/단체지원/교육 등 연구자 활동을 지속하도록 DBpia가 지원하고 있어요.
커뮤니티
연구자들이 자신의 연구와 전문성을 널리 알리고, 새로운 협력의 기회를 만들 수 있는 네트워킹 공간이에요.
논문 기본 정보
- 자료유형
- 학술저널
- 저자정보
- 저널정보
- 대한응급의학회 Clinical and Experimental Emergency Medicine Clinical and Experimental Emergency Medicine 제12권 제3호
- 발행연도
- 2025.9
- 수록면
- 251 - 258 (8page)
- DOI
- 10.15441/ceem.24.294
이용수
초록· 키워드
Objective: Chest pain, a common emergency department presentation, requires rapid evaluation. The current gold standard of care is serial troponin measurements from blood draws along with an electrocardiogram and clinical presentation. However, an optical technology-based noninvasive wearable device, the Infrasensor, which can rapidly and transcutaneously assesses cardiac troponin I (cTnI), was recently developed. We aimed to perform a pilot study to evaluate the performance of the Infrasensor in cTnI defined cohorts.Methods: This was a 10-hospital prospective observational study in healthy US subjects with a normal cTnI level and in patients with an elevated local cTnI level. Healthy subjects as determined by a negative questionnaire and bloodwork underwent 3-minute Infrasensor measurement and levels of high-sensitivity cTnI (hs-cTnI), n-terminal pro-B-type natriuretic peptide (NTproBNP), creatinine, and glycosylated hemoglobin (HbA1c) were evaluated from blood. Patients with elevated cTnI had the same Infrasensor and blood sample measurements. Using a fivefold cross-validation technique, cTnI-based binary classification models that did and did not include age were trained on 80% and validated on 20% of the dataset (n=168; elevated hs-cTnI equally partitioned into five nearly equally-sized subsets ). Results: Of 840 patients, 727 (87.5%) had normal (nonelevated) cTnI levels while the remaining 113 had elevated cTnI. Median age was 61 years (interquartile range, 52–71 years) for the elevated cohort and 48 years (interquartile range, 32–57 years) for the nonelevated. Overall, 416 (50.5%) were female, with 33 of 113 (29.2%) in the elevated cohort and 383 of 727 (52.7%) in the nonelevated cohort. Overall, the sensitivity, specificity, negative and positive predictive values of the Infrasensor for identifying elevated cTnI were 0.90, 0.70, 0.98 and 0.48, respectively, with a C-statistic of 0.90 (95% confidence interval, 0.89–0.99).Conclusion: The Infrasensor accurately identifies elevated cTnI within 3 minutes of application.
상세정보 수정요청해당 페이지 내 제목·저자·목차·페이지정보가 잘못된 경우 알려주세요!
목차
등록된 정보가 없습니다.