메뉴 건너뛰기
소속 기관 / 학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
고객센터 ENG
주제분류

논문 기본 정보

저자정보
(Korea National Railway) (Korea National Railway) (Korea National Railway) (Korea National Railway)
저널정보
대한전기학회 전기학회논문지 전기학회논문지 제75권 제11호
오류 신고하기

피인용 0

검색

    초록·키워드

    Neutral sections in 25 kV AC railways require trains to coast with the main circuit breaker open, which temporarily interrupts traction. Regenerative-energy use also varies with the power-receptive capacity of the feeding section and the upstream grid. The operational and energy effects of a bidirectional continuous feeding system based on a modular multilevel converter (MMC) were quantified using a one-dimensional train-motion model and an energy-balance calculation. A 300 km/h train was evaluated for effective de-energized lengths of 200–800 m and gradients of 0–15‰. At 400 m, speed loss increased from 1.28 km/h on level track to 3.23 km/h at 12‰ and reached 7.50 km/h at 800 m and 15‰. The calculated delay to initial-speed recovery remained below 0.4 s. When regenerative receptivity increased from 0.32 to 0.88, the reduction in normalized net supply energy ranged from 5.8% to 18.6% as the recoverable braking-energy ratio varied from 0.10 to 0.30. The reduction was 12.0% at a ratio of 0.20. Field validation requires synchronized measurements of train operation and feeder power to replace the assumed vehicle parameters and receptivities.

    최근 본 자료 전체보기