인문학
사회과학
자연과학
공학
의약학
농수해양학
예술체육학
복합학
지원사업
학술연구/단체지원/교육 등 연구자 활동을 지속하도록 DBpia가 지원하고 있어요.
커뮤니티
연구자들이 자신의 연구와 전문성을 널리 알리고, 새로운 협력의 기회를 만들 수 있는 네트워킹 공간이에요.
초록·키워드
Abstract Robotics in medicine is associated with precision, accuracy, and replicability. Several robotic systems are used in spine surgery. They are all considered shared-control systems, providing "steady-hand" manipulation instruments. Although numerous studies have testified to the benefits of robotic instrumentations, they must address their true accuracy. Our study used the Mazor system under several situations and compared the spatial accuracy of the pedicle screw (PS) insertion and its planned trajectory. We used two cadaveric specimens with intact spinal structures from C7 to S1. PS planning was performed using the two registration methods (preopCT/C-arm or CT-to-fluoroscopy registration). After planning, the implant spatial orientation was defined based on six anatomic parameters using axial and sagittal CT images. Two surgical open and percutaneous access were used to insert the PS. After that, another CT acquisition was taken. Accuracy was classified into optimal, inaccurate and unacceptable according to the degree of screw deviation from its planning using the same spatial orientation method. Based on the type of spatial deviation, we also classified the PS trajectory into 16 pattern errors. Seven (19%) out of 37 implanted screws were considered unacceptable (deviation distances > 2.0 mm or angulation > 5°), and 14 (38%) were inaccurate (> 0.5 mm and ≤ 2.0 mm or > 2.5° and ≤ 5°). CT-to-fluoroscopy registration was superior to preopCT/C-arm (average deviation in 0.9 mm vs. 1.7 mm, respectively, p < 0.003), and percutaneous was slightly better than open but did not reach significance (1.3 mm vs. 1.7 mm, respectively). Regarding pattern error, the tendency was to have more axial than sagittal shifts. Using a quantitative method to categorize the screw 3D position, only 10.8% of the screws were considered unacceptable. However, with a more rigorous concept of inaccuracy, almost half were non-optimal. We also identified that, unlike some previous results, the O-arm registration delivers more accurate implants than the preopCT/C-arm method.
#Medicine
#Fluoroscopy
#Cadaveric spasm
#Orientation (vector space)
#Sagittal plane
#Robotics
#Percutaneous
#Artificial intelligence
#Accuracy and precision
#Image-guided surgery
#Standard deviation
#Nuclear medicine
#Computer vision
#Biomedical engineering
#Robot
#Computer science
#Surgery
#Radiology
#Mathematics
인공지능 문자 인식 모델을 통해 추출된 텍스트로, 일부 오타나 오류가 포함될 수 있으나 지속적으로 개선 중입니다.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.
오류를 발견하셨다면 해당 부분을 드래그한 후 ' 를 통해 신고해주세요.