Experiments were performed for the real sized 13 reinforced concrete columns of 350x350x3360mm with normal and high strength concrete in order to observe the fire-damaged residual strength of these columns. Columns were heated according to the ISO heating curve. Main experimental parameters were: magnitude of axial load, heating time, cover thickness, and eccentricity. Effects of these parameters were experimentally quantified. Although significant reduction in residual strength was observed for the columns exposed to longer heating time, little effects on the residual strength by cover thickness and magnitude of axial load were observed. Repairing did not lead to the improvement of residual strength. Strengthening by wrapping the GFRP sheets, however, recovered the fire-damaged column strength up to 97% of axial strength of the prototype undamaged column.