메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
저널정보
한국사회체육학회 한국사회체육학회지 한국사회체육학회지 제56권 제2호
발행연도
2014.5
수록면
877 - 884 (8page)
DOI
10.51979/KSSLS.2014.05.56.877

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

이 논문의 연구 히스토리 (2)

초록· 키워드

오류제보하기
The purpose of this study was to verify the differences on power generation of lower limb and the optimum frequency to maximize the power. The subject of this study was chosen as 10 able-bodied male students in college on N university, Chungcheongnam-do, whom there is no medical history about motor disturbance, paresthesia, nervous system, musculoskeletal system, and listened about the purposes, methods and risks of study, and written the participation agreement. Using random sampling method, 10 subjects kept an upright posture on the Turbo-Trainer during 5 minutes as the frequency of 8㎐, 26㎐, 40㎐ in order to fit each order, and then practiced 5 times multiple jump on the Accupower for measuring the lower limb power, finally measured maximum power, mean power, maximum jump height and mean jump height through the ground reaction force. Using SPSS 18.0, the data process of this study calculated as mean (M) and standard deviation (SD) of all measured value, used one-way repeated measure ANOVA in order to verify the significant difference between maximum power, mean power, maximum jump height, mean jump height at each frequency. The significant level of hypothesis verification is set-up as α=.05. The results of this study are follows. 1) The maximum power of whole body vibration showed significant differences at the 26㎐ only compared with before implementation(p <.01). 2) The mean power of whole body vibration showed significant differences at the 26㎐ only compared with before implementation(p<.05). 3) The maximum jump height of whole body vibration showed significant differences at the 26㎐ only compared with before implementation(p<.05). 4) The mean jump height of whole body vibration showed significant differences at the 26㎐ only compared with before implementation(p<.05). In summary, during whole body vibration according to frequency affect to lower limb power at 26㎐, the optimum frequency except mean jump height has verified at 26㎐ due to the significant difference has been appeared at the maximum power, mean power, maximum jump height except mean jump height. Therefore, this study is provided to sports scientist, supervisor, coach, trainer and player whom need the enhancement of lower limb power as scientific basic data and will be contributed to their performance enhancement.

목차

등록된 정보가 없습니다.

참고문헌 (21)

참고문헌 신청

이 논문의 저자 정보

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0