메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
S. M. Mahdi Alavi (University of British Columbia) Fidel Vila-Rodriguez (University of British Columbia) Adam Mahdi (University of Surrey) Stefan M. Goetz (University of Cambridge)
저널정보
대한의용생체공학회 Biomedical Engineering Letters (BMEL) Biomedical Engineering Letters (BMEL) Vol.13 No.2
발행연도
2023.5
수록면
119 - 127 (9page)
DOI
https://doi.org/10.1007/s13534-022-00259-3

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
This paper proposes an efficient algorithm for automatic and optimal tuning of pulse amplitude and width for sequentialparameter estimation (SPE) of the neural membrane time constant and input–output (IO) curve parameters in closed-loopelectromyography-guided (EMG-guided) controllable transcranial magnetic stimulation (cTMS). The proposed SPE is performedby administering a train of optimally tuned TMS pulses and updating the estimations until a stopping rule is satisfiedor the maximum number of pulses is reached. The pulse amplitude is computed by the Fisher information maximization. The pulse width is chosen by maximizing a normalized depolarization factor, which is defined to separate the optimizationand tuning of the pulse amplitude and width. The normalized depolarization factor maximization identifies the critical pulsewidth, which is an important parameter in the identifiability analysis, without any prior neurophysiological or anatomicalknowledge of the neural membrane. The effectiveness of the proposed algorithm is evaluated through simulation. The resultsconfirm satisfactory estimation of the membrane time constant and IO curve parameters for the simulation case. By definingthe stopping rule based on the satisfaction of the convergence criterion with tolerance of 0.01 for 5 consecutive times forall parameters, the IO curve parameters are estimated with 52 TMS pulses, with absolute relative estimation errors (AREs)of less than 7%. The membrane time constant is estimated with 0.67% ARE, and the pulse width value tends to the criticalpulse width with 0.16% ARE with 52 TMS pulses. The results confirm that the pulse width and amplitude can be tunedoptimally and automatically to estimate the membrane time constant and IO curve parameters in real-time with closed-loopEMG-guided cTMS.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0