메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색
질문

논문 기본 정보

자료유형
학술저널
저자정보
Jong-Chan Baik (Pusan National University Dental Hospital) Youn-Kyung Choi (Pusan National University Hospital) Yonghun Cho (Pusan National University) Yunju Baek (Pusan National University) Sung-Hun Kim (Pusan National University Dental Hospital) Seong-Sik Kim (Pusan National University Dental Hospital) Soo-Byung Park (Pusan National University Dental Hospital) Ki Beom Kim (Saint Louis University) Yong-Il Kim (Pusan National University Dental Hospital)
저널정보
대한치과교정학회 대한치과교정학회지 대한치과교정학회지 제54권 제6호
발행연도
2024.11
수록면
359 - 373 (15page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색
질문

초록· 키워드

오류제보하기
Objective: This study aimed to investigate the effect of three-dimensional (3D) printed clear aligners (CA) with different designs on the extrusion of mandibular premolars using a force/moment measurement system and digital image correlation (DIC). Methods: The forces and moments applied to the mandibular canines, first and second premolars were measured using a multi-axis force/moment transducer when an extrusion of 0.5 ㎜ was planned, assuming the mandibular first premolars were intruded by 1 ㎜. In addition, displacement and strain changes in the CA were analyzed using the DIC method. CA designs were categorized based on the presence of first premolar attachment and subdivided into equigingival margins, 1-㎜ extended margins, equi-margins with 1-㎜ thickness and height, and equi-margins with 1-mm reduced buccolingual width. The CA was printed directly at a thickness of 0.5 ㎜, and the experiments were conducted at 37℃. Results: The results showed that attachment played an important role in the extrusion of first premolars in both the force/moment measurement system and the DIC method. Intrusion was observed without attachment, even though extrusion was planned. CA designs apply greater force to the cervical region by extending the margin or reducing the buccolingual width, thereby improving extrusion efficiency. Conclusions: Force and moment changes in direct 3D printed CA are complex and difficult to predict; however, modifying aligner designs, such as extending the margin or reducing buccolingual width, and using appropriate attachments could minimize unwanted tooth movement, optimize planned treatment, and increase treatment predictability.

목차

INTRODUCTION
MATERIALS AND METHODS
RESULTS
DISCUSSION
CONCLUSIONS
REFERENCES

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문과 함께 이용한 논문

최근 본 자료

전체보기

댓글(0)

0

UCI(KEPA) : I410-151-25-02-092177242