메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Marashdeh Mohammad W. (Imam Mohammad Ibn Saud Islamic University (IMSIU)) Sallam Fawzy H. (Nuclear Materials Authority) Abd El-Aziz Ahmed M. (Ultrasonic Laboratory, National Institute of Standards) Elkhatib Mohamed I. (Basic Science Department, Higher Institute of Engineering and Technology) Alanazi Sitah f. (Imam Mohammad Ibn Saud Islamic University (IMSIU)) Aljaafreh Mamduh J. (Imam Mohammad Ibn Saud Islamic University (IMSIU)) Al-Hmoud Mohannad (Imam Mohammad Ibn Saud Islamic University (IMSIU)) Mahmoud K.A. (Ural Federal University)
저널정보
한국원자력학회 Nuclear Engineering and Technology Nuclear Engineering and Technology Vol.56 No.7
발행연도
2024.7
수록면
2,740 - 2,747 (8page)
DOI
10.1016/j.net.2024.02.035

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
The sintering process acquired ferromagnetic copper ferrite ceramic material with a small concentration of Ni ion at 1100 ◦C for 1 h. Previously, copper ferrite with Ni proportions powder was acquired by the wet chemical process according to the relation CuFe2-xNixO4 where x takes values 0.0, 0.015, 0.03, 0.04, and 0.05. The role of Ni ion in the copper ferrite structure was investigated by X-ray analysis, Scanning electron microscope, EDX analysis, and density measurements. The gamma-ray shielding properties for the fabricated CuFeNiO ceramics samples were evaluated using the Monte Carlo simulation method. The obtained results show an enhancement in the linear attenuation coefficient for the fabricated ceramics with increasing the insertions of Ni ions within the fabricated samples, where increasing the Ni ions concentration between 0 and 1.19 wt% increases the linear attenuation by between 1.581 and 1.771 cm 1 (at 0.103 MeV), 0.304–0.338 cm 1 (at 0.662 MeV), and 0.160–0.178 cm 1 (at 2.506 MeV), respectively. Simultaneously, the radiation protection efficiency for a 1 cm thickness of the fabricated samples increased between 14.8 and 16.3% with increasing the Ni ions between 0 and 1.19 wt%. Although the Ni doping concentration does not exceed 1.5 wt% of the total composition of the fabricated ceramics, the shielding capacity of the fabricated ceramics was enhanced by more than 11%, along the studied energy interval. Therefore, the fabricated samples can be used in gamma-ray shielding applications

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0