Wali, Arvin R. (Department of Neurosurgery, University of California, San Diego, La Jolla, CA, USA) Sindewald, Ryan W. (Department of Neurosurgery, University of California San Diego, CA, USA) Brandel, Michael G. (Department of Neurosurgery, University of California San Diego, CA, USA) Bravo, Javier (Department of General Surgery, University of California, San Diego, USA) Steinberg, Jeffrey A. (Department of Neurosurgery, University of California San Diego, CA, USA) Pannell, J. Scott (Department of Neurological Surgery, University of California, San Diego, USA) Khalessi, Alexander A. (Department of Neurological Surgery, University of California, San Diego, USA) Santiago-Dieppa, David R. (Department of Neurological Surgery, University of California, San Diego, USA)
저널정보
대한뇌혈관외과학회 Journal of Cerebrovascular and Endovascular Neurosurgery Journal of Cerebrovascular and Endovascular Neurosurgery Vol.26 No.3
발행연도
2024.9
수록면
260 - 264 (5page)
DOI
10.7461/jcen.2024.E2023.09.003

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
Objective: We sought to investigate how priming the tube between air versus air mixed with saline ex vivo influenced suction force. We examined how priming the tube influenced peak suction force and time to achieve peak suction force between both modalities.Methods: Using a Dwyer Instruments (Dwyer Instruments Inc., Michigan City, IN, USA), INC Digitial Pressure Gauge, we were able to connect a .072 inch aspiration catheter to a rotating hemostatic valve and to aspiration tubing. We recorded suction force measured in negative inches of Mercury (inHg) over 10 iterations between having the aspiration tube primed with air alone versus air mixed with saline. A test was used to compare results between both modalities.Results: Priming the tube with air alone compared to air mixed with saline was found to have an increased average max suction force (-28.60 versus -28.20 in HG, p<0.01). We also identified a logarithmic curve of suction force across time in which time to maximal suction force was more prompt with air compared with air mixed with saline (13.8 seconds versus 21.60 seconds, p<0.01).Conclusions: Priming the tube with air compared to air mixed with saline suggests that not only is increased maximal suction force achieved, but also the time required to achieve maximal suction force is less. This data suggests against priming the aspiration tubing with saline and suggests that the first pass aspiration primed with air may have the greatest suction force.

목차

등록된 정보가 없습니다.

참고문헌 (0)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

최근 본 자료

전체보기

댓글(0)

0