메뉴 건너뛰기
.. 내서재 .. 알림
소속 기관/학교 인증
인증하면 논문, 학술자료 등을  무료로 열람할 수 있어요.
한국대학교, 누리자동차, 시립도서관 등 나의 기관을 확인해보세요
(국내 대학 90% 이상 구독 중)
로그인 회원가입 고객센터 ENG
주제분류

추천
검색

논문 기본 정보

자료유형
학술저널
저자정보
Jeong-Sook Seo (Inje University Busan Paik Hospital) Young-Ah Park (Inje University Busan Paik Hospital) Jin Hong Wi (Inje University Busan Paik Hospital) Han-Young Jin (Inje University Busan Paik Hospital) Il-Yong Han (Inje University Busan Paik Hospital) Jae-Sik Jang (Inje University Busan Paik Hospital) Tae-Hyun Yang (Inje University Busan Paik Hospital) Dae Kyeong Kim (Inje University Busan Paik Hospital) Dong-Soo Kim (Inje University Busan Paik Hospital)
저널정보
한국심초음파학회 Journal of Cardiovascular Imaging Journal of Cardiovascular Imaging 제29권 제2호
발행연도
2021.1
수록면
123 - 132 (10page)

이용수

표지
📌
연구주제
📖
연구배경
🔬
연구방법
🏆
연구결과
AI에게 요청하기
추천
검색

초록· 키워드

오류제보하기
BACKGROUND: Studies comparing left atrial (LA) function after surgical closure or percutaneous closure in patients with an atrial septal defect (ASD) are lacking. METHODS: Between 1 and 3 years after ASD treatment, we retrospectively analyzed the medical records and transthoracic echocardiographic images of patients who had been diagnosed with an ASD after 20 years of age and who had undergone surgical closure (ASD-S) or percutaneous device closure (ASD-D). We measured LA peak systolic, early diastolic, and late diastolic strain values using 2-dimensional (2D) speckle tracking echocardiography (STE) and calculated reservoir, conduit, and contraction strain. RESULTS: The reservoir strain value of the ASD-D groups was 25.2% ± 7.4%, which was lower compared to the control group (33.6% ± 5.5%) (p = 0.004). The LA conduit strain and the LA contraction values of the ASD-D group were also lower compared to the control group (?13.8% ± 5.8% vs. ?20.4% ± 4.7%, p = 0.034; ?11.3% ± 4.2% vs. ?13.2% ± 2.5%, p = 0.037, respectively). The reservoir, conduit, and contraction strains of the ASD-S group were 27.8% ± 8.8%, ?15.3% ± 6.4%, and ?12.5% ± 5.8%, respectively, and were not different from those of the control group or the ASD-D group. CONCLUSIONS: The 2D STE is a suitable method for evaluating LA function after ASD closure. Our results demonstrate that 1 year after device closure, the LA reservoir, conduit and contraction function were reduced in ASD-D group compared to healthy controls, while there was no difference between the ASD-S and ASD-D groups.

목차

등록된 정보가 없습니다.

참고문헌 (30)

참고문헌 신청

함께 읽어보면 좋을 논문

논문 유사도에 따라 DBpia 가 추천하는 논문입니다. 함께 보면 좋을 연관 논문을 확인해보세요!

이 논문의 저자 정보

최근 본 자료

전체보기

댓글(0)

0